Klima Global General Trading LLC

Hygienic air handling units

Climacs Hygienic Air Handling Unit- Klima Global
Eurovent certificate logo
TUVSUD compliance
CE logo
TSEK logo

CLIMACS Hygienic Air Handling Units redefine efficiency with their premium-quality features, engineered to exceed industry standards. Designed to meet the stringent hygienic requirements outlined in DIN 1946-4 and VDI 6022, these units are ideal for environments demanding uncompromised cleanliness, such as hospitals, pharmaceutical production facilities, laboratories, and cleanrooms.

Compliance with Hygienic Standards

The units are meticulously crafted to adhere to critical hygiene-focused standards, ensuring the use of high-quality materials, enhanced accessibility, and superior cleanability:

  • DIN 1946-4: 2018-09
  • VDI 6022-1: 2018-01
  • VDI 3803-1: 2020-05
  • DIN EN 13053: 2020-05

Technical Highlights

The CLIMACS Hygienic Air Handling Units boast a range of advanced features, including:

  • 50 mm Rockwool Insulation: Providing exceptional thermal and acoustic insulation for optimal performance.
  • Hygienic Compliance: Fully aligned with the rigorous standards of DIN 1946-4 and VDI 6022.
  • Stainless Steel Inner Components: Incorporating a robust inner sheet and a hygienic drain pan for enhanced durability and cleanliness.
  • Direct Drive Plug Fans: Delivering high energy efficiency and minimal maintenance requirements.
  • Smooth Internal Surfaces: Designed to ensure effortless cleaning and minimize contamination risks.

With their state-of-the-art design and adherence to the highest hygiene standards, CLIMACS Hygienic Air Handling Units stand as a trusted solution for critical applications requiring pristine air quality.

What is a Hygienic Air Handling Unit (Hygienic AHU)?

A Hygienic Air Handling Unit (Hygienic AHU) is an advanced type of Air Handling Unit specifically engineered to uphold stringent air purity and hygiene requirements. These units play a pivotal role in environments where maintaining impeccable cleanliness and air quality is critical, such as hospitals, pharmaceutical production facilities, laboratories, and cleanrooms. Below is a comprehensive exploration of their features, applications, and advantages.

Key Features of Hygienic AHUs

Hygienic AHUs incorporate cutting-edge technology and materials to ensure superior air quality and sanitary conditions:

  1. High-Efficiency Filtration: Equipped with HEPA (High-Efficiency Particulate Air) or ULPA (Ultra-Low Penetration Air) filters that remove up to 99.99% of airborne contaminants, including bacteria and viruses.

  2. Smooth, Non-Porous Surfaces: Internal surfaces are crafted from materials resistant to microbial growth and designed for easy cleaning.

  3. Anti-Microbial Coatings: Components are treated with anti-microbial finishes to prevent contamination and biofilm formation.

  4. Seamless Construction: Designed with minimal joints and seams to eliminate areas where particles or microorganisms can accumulate.

  5. UV-C Germicidal Lamps: Integrated UV-C lamps in the airflow path sterilize air by neutralizing bacteria, viruses, and mold spores.

  6. Pressure Control Systems: Advanced monitoring and control systems maintain the correct pressure differentials between zones, critical for contamination control.

Applications of Hygienic AHUs

Hygienic AHUs are indispensable in settings requiring unparalleled air cleanliness:

  • Healthcare Facilities: Operating rooms, isolation wards, and intensive care units (ICUs) demand sterile air to minimize infection risks.

  • Pharmaceutical Manufacturing: Critical areas for drug production must comply with strict contamination control protocols.

  • Laboratories: Research facilities, particularly those handling hazardous biological materials, require controlled air quality for safety and precision.

  • Food and Beverage Industry: Used in processing and packaging zones to prevent airborne contamination of products.

Benefits of Hygienic AHUs

Hygienic AHUs offer multiple advantages that make them essential for sensitive environments:

  • Exceptional Air Quality: Ensures the highest level of purification, safeguarding sensitive processes and occupants’ health.

  • Regulatory Compliance: Meets or exceeds the rigorous standards for air hygiene in healthcare, pharmaceutical, and cleanroom applications.

  • Infection Prevention: Reduces airborne transmission of pathogens, a critical factor in hospitals and sterile production facilities.

  • Durability and Efficiency: Engineered for reliable, continuous operation with low maintenance requirements.

Hygienic AHUs vs. Standard AHUs

While standard AHUs are suitable for general HVAC purposes, Hygienic AHUs are specifically designed for environments requiring enhanced air purity. Key differentiators include:

  • Filtration Efficiency: Advanced filters in Hygienic AHUs outperform standard systems.
  • Anti-Microbial Features: Hygienic units incorporate specialized coatings and UV technology absent in regular AHUs.
  • Construction Quality: Seamless, easy-to-clean designs distinguish Hygienic AHUs from their standard counterparts.

In summary, Hygienic Air Handling Units are indispensable in environments where maintaining exceptional air quality and strict hygiene standards is paramount. Their specialized features and robust design make them the optimal choice for industries like healthcare, pharmaceuticals, and cleanroom operations, ensuring safety, compliance, and operational excellence.

FAQ

What is the primary purpose of a Hygienic AHU?

Hygienic AHUs are designed to provide clean, sterile air in environments where air purity and hygiene are critical, such as hospitals, pharmaceutical facilities, laboratories, and cleanrooms. They ensure compliance with stringent air quality and contamination control standards.

Hygienic AHUs incorporate advanced features like HEPA or ULPA filters, anti-microbial coatings, seamless construction, and UV-C germicidal lamps, making them suitable for applications where hygiene is paramount. Standard AHUs, on the other hand, are designed for general HVAC purposes without these specialized features.

Hygienic AHUs are widely used in:

  • Healthcare (operating rooms, ICUs, isolation wards)
  • Pharmaceutical manufacturing
  • Biotechnology and research laboratories
  • Food and beverage production
  • Semiconductor and electronics cleanrooms

Hygienic AHUs use HEPA (High-Efficiency Particulate Air) or ULPA (Ultra-Low Penetration Air) filters capable of capturing up to 99.99% of airborne particles, including bacteria, viruses, and other contaminants.

Yes, Hygienic AHUs are engineered for energy efficiency with features like direct drive plug fans, optimized filtration systems, and intelligent controls that minimize energy consumption while maintaining performance.

Yes, Hygienic AHUs comply with stringent standards such as:

  • DIN 1946-4: Requirements for healthcare HVAC systems.
  • VDI 6022: Guidelines for hygiene in ventilation and air-conditioning systems.
  • DIN EN 13053: Energy performance and functionality standards.

Yes, manufacturers often offer customization options for Hygienic AHUs to meet the unique requirements of industries like pharmaceuticals, healthcare, or food processing. Please contact us for customization as per your need.

Hygienic AHUs are constructed with high-quality materials such as stainless steel and feature robust components designed for continuous, long-term operation in demanding environments.

While the initial investment may be higher than standard AHUs, their reliability, energy efficiency, and ability to prevent costly contamination issues make them a cost-effective solution in the long run.

Yes, Hygienic AHUs are designed to manage high airflow volumes while maintaining strict air quality and hygiene standards, making them suitable for both small-scale and large-scale applications.